Fanuc 11 Ladder G codes

Spindle 10v CN1 – CA1 Pin 32 – pin 19 Pin 31 – pin 7 Decx m1-38 Decz m1-39 Dec x,y,z: G64.5, G68.5, G72.5 +lx, -lx, +ly, -ly, +lz, -lz G64.0, G64.1, G68.0, G68.1, G72.0, G ST G5.0 *SP G0.5 EDIT G3.6 MEM G3.5 MDI G3.3 TAPE G3.4 HANDLE G3.1 STEP G3.0 RT G6.7 JOG G3.2 +JOGX G65.0 -X G65.1 +Y G69.0 -Y G69.1 +Z G73.0 -Z G73.1 MLK G4.7 SBK G4.3 ABS G4.5 ZRN G2.7 MP1 G6.2 MP2 G6.3 MP4 G6.4 ROV1 G6.5 ROV2 G6.6 *ITX G64.4 *ITY G68.4 *ITZ G72.4 FIN G5.1 ERROR G0.7 Emg G0.4 Fanuc 10 yellow Mode MD1 G12.0 Mode MD2 G12.1 Mode MD4 G12.2

read more

930 CPU Interrupt

The 930 CPU Interrupt often occurs when there’s a disruption to the 5V logic supply. This is usually due to electrical noise in the machine or in the electrical panel. FANUC misleads you in the manual by suggesting replacement of the master board. This rarely solves the problem. This fault is almost always caused by problems in the grounding or electrical arc suppression of AC and DC devices. Often, the problem will not occur if you leave the machine in Estop after powering up. Once you take it out of Estop, hydraulics, etc come on and that’s when the problem usually...

read more

Fanuc 10 Alarm IO030 check sum error

This means that a part of the memory has been corrupted. Have you just started getting this alarm after loading a new program to the control? This usually happens when loading to the control. You can sometimes find and delete the program if you know which one gave you the problem. Best solution is to clear memory and reload programs. First thing you have to do is backup all of your programs. If your 8000 and 9000 programs are locked you must unlock them otherwise they will not read out of the CNC when doing a backup. Parameter 0011.0 unlocks the 8000 Parameter 2201.0 unlocks the 9000 Once you...

read more

Zero return problems

What causes zero return position to change or loss of it on any CNC? Crash– causes motor coupling to slip or drive miscalculate position Chips piled in area of deceleration dog (switched machines only) Zero return switch(switched machines only)- If Limit switch-does it move freely (clean it) If prox switch, then wipe chips off Face Backup Battery needs replacement keeps encoder position when power is shut off (Warning Most machines require replacement with power up) One revolution pulse on the encoder happens to be really close to the drop off point of the decel dog(Switched machines...

read more

Tuyển dụng

Để phục vụ cho nhu cầu phát triển sắp tới, Savotech tuyển dụng các vị trí sau

02 Kỹ thuật viên Cơ

02 Kỹ thuật viên Điện

01 Kỹ thuật viên Điện tử

Các bạn yêu thích lĩnh vực máy công cụ, các loại máy CNC, muốn tìm tòi nghiên cứu hãy đến với chúng tôi.

Xin liên hệ qua mail: tuanfanuc@gmail.com

Hoặc SMS, Zalo, Viber 0983574244

Powered by WordPress Popup